Timeguard 202.0.000 User Manual

Browse online or download User Manual for Clock Timeguard 202.0.000. Timeguard 202.0.000 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Art. Nr. 202 0 050
Art. Nr. 202 0 000
1103000311 © 11.08 Theben HTS
Presence detector
ECO-IR 180A
ECO-IR 360A
F
GB
D
E
I
NL
Bedienungsanleitung 2
Notice d
´utilisation 22
Installation manual 4
2
Manual de instrucciones 6
2
Istruzioni per l'uso 8
2
Gebruikershandleiding 102
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - ECO-IR 360A

Art. Nr. 202 0 050Art. Nr. 202 0 0001103000311 © 11.08 Theben HTSPresence detectorECO-IR 180AECO-IR 360AFGBDEINLBedienungsanleitung 2Notice d´utilisa

Page 2 - Table of contents

505. Start-up5.1 SettingsSet the unit as shown on the rear of the disassembled sensor head. Note the setting guidelines in the following tables for de

Page 3 - 1. Safety

51 Switch-off time delay «Light»Set the desired minimum switch-off delay time for the «Light» switching contact on the potentiometer.Trans

Page 4 - 2.3 Switching contact «Light»

525.3 Behaviour on switching onAfter you have dened the settings, connect the upper part to the power section. Ensure that the labelling is aligned o

Page 5 - 2.4 Switching contact «HVAC»

53The service phase is completed automatically after 10 minutes. Repeat the setting procedure if it is necessary to modify one of the three variables.

Page 6 - 3. Detection Range

546.Technicalspecications*) Use of T5-FL: When using T5-FL lamps with a comparable wattage, the same number of electronic ballasts may be connected

Page 7 - ECO-IR 180A: ECO-IR 360A:

55GBCommon power module ECO-IR 540B2Nominal voltage 230V± 10%, 50HzSwitching contact A«Light»Contact design 230V± 10%Max switching capacity 1400VAMax.

Page 8 - 4.2 Preparations

567. Warranty declarationTheben HTS presence detectors are manufactured and quality-tested with the utmost care using state-of-the-art technologies

Page 9 - 4.3 Connecting the ECO-IR

57GB8. TroubleshootingFault Cause RemedyLighting on after the detector is connected.Both outputs are closed for 90 s after the detector has been conne

Page 10 - 5. Start-up

58Subject to change without prior notice. Errors and omissions excepted.Dimensions ECO-IR 180A5611470705646,3358048704585

Page 11

59Declaration of CE conformityThis device complies with the protection regulations of the EMC directive 2004/108/EC and of the Low Voltage directive 2

Page 12 - 5.3 Behaviour on switching on

42 EnglishInstallation manualPresence detector ECO-IR 180AECO-IR 360ATable of contents1. Safety . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13

60Theben AGHohenbergstrasse 32, DE-72401 HaigerlochTel. +49 (0) 74 74 692 - 0Fax +49 (0) 74 74 692 - 150HotlineTel. +49 (0) 74 74 692 - 369Fax +49 (

Page 14 - 6.Technicalspecications

43Thank you for choosing a Theben HTS presence detector and putting your trust in us.1. SafetyDANGER !Any work on electrical systems must exc

Page 15 - @ 2A m, 230V~2A m

442. Function and performance characteristics2.1 Presence detectionHigh-sensitivity PIR sensors and an intelligent lens system provide complete covera

Page 16 - 7. Warranty declaration

45When using suspended lighting, we recommend that you integrate the de-tector directly in the lamps or provide a sufcient lateral clearance. When us

Page 17 - 8. Troubleshooting

463. Detection Range3.1 Detection Range ECO-IR 180A for wall mountingThe recommended mounting height is 2,2m. Mounting the device in the hei

Page 18 - Dimensions ECO-IR 180A

47ECO-IR 180A: ECO-IR 360A:GBo2,2 m1 2 356 7 8040213o

Page 19

484. Mounting and connecting the device4.1 Type of mounting Both ECO-IR models must be mounted in housings (surface-mounted or con-cealed installation

Page 20

494.4 Stepping switch/time switchesThe ECO-IR must not be used to trigger stepping switches. The unit may only be connected in parallel to time switch

Comments to this Manuals

No comments