Timeguard 200.0.000 User Manual

Browse online or download User Manual for Clock Timeguard 200.0.000. Timeguard 200.0.000 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1103020206 © 08.08 Theben HTS
Art. Nr. 200 0 050
Art. Nr. 200 0 000
Presence detector
PresenceLight 180
PresenceLight 360
F
GB
D
E
I
NL
Bedienungsanleitung 2
Notice d´utilisation 22
Installation manual 42
Manual de instrucciones 62
Istruzioni per l'uso 82
Gebruikershandleiding 102
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - PresenceLight 360

1103020206 © 08.08 Theben HTSArt. Nr. 200 0 050Art. Nr. 200 0 000Presence detectorPresenceLight 180PresenceLight 360FGBDEINLBedienungsanleitung 2Noti

Page 2 - Table of contents

504.3 Behaviour on switching onWhenever the unit is energised, the detector goes through 3 phases. 1. Start-up phase (30sec)LED ashes every second, s

Page 3 - 1. Safety

515. Additional wiring examples5.1 Parallel circuit operation of multiple detectorsDirectly connect the switching contacts of multiple detectors in pa

Page 4

526. Test modeThe test mode serves to check the presence detection and the wiring.6.1 Setting the test mode with potentiometerSet potentiometer «min.»

Page 5 - 3. Location / Installation

537. Technical specicationsPresence Detector PresenceLight 360Detection range horizontal vertical360º120ºRecommended mounting height 2.0m - 3mMaxi

Page 6

54PresenceLight 360, PresenceLight 180Switching contact 230V ± 10%, 50HzIn-line fuse max. 10AMax. switching capacity incandescent lamps, halogen1400

Page 7 - 3.4 Protection Class IP54

55*) Use of T5-FL: When using T5-FL lamps with a comparable wattage, the same number of electronic ballasts may be connected to the detector’s switchi

Page 8 - 4. Start-up

56ReturnsIn the event of a warranty claim please send the unit together with the delivery note and a brief description of the fault to the dealer conc

Page 9

57Dimensions PresenceLight 360GB4845.770564116040,5402786

Page 10 - 3. Operation

58Dimensions PresenceLight 180706041156403240,5864836

Page 11 - 5. Additional wiring examples

59Subject to change without prior notice. Errors and omissions excepted.Dimensions surface frame for PresenceLight 360, PresenceLight 180Declaration

Page 12 - 6. Test mode

42 EnglishInstallation manualPresence detector PresenceLight 180PresenceLight 360Table of contents1. Safety ...

Page 13 - 7. Technical specications

60Theben AGHohenbergstrasse 32, DE-72401 HaigerlochTel. +49 (0) 74 74 692 - 0Fax +49 (0) 74 74 692 - 150HotlineTel. +49 (0) 74 74 692 - 369Fax +49 (

Page 14

43Thank you for choosing a Theben HTS presence detector and putting your trust in us.1. SafetyDANGER !Any work on electrical systems must exclusively

Page 15 - 8. Warranty declaration

442. Function and performance characteristicsThe presence detectors PresenceLight 360 and PresenceLight 180 detect persons within a room on account of

Page 16 - 9. Troubleshooting

453. Location / Installation3.1 Detection Range PresenceLight 360The ideal mounting height is 2,0 - 3,0m. The sensitivity of the detector decreases wi

Page 17 - Dimensions PresenceLight 360

46PresenceLight 360: PresenceLight 180:2310m02311233.50.83.5Lux3,5 3,532112303,532 112 30oo2,2m123567804021302132135678456784

Page 18 - Dimensions PresenceLight 180

473.3 ConnectionThe presence detector must be ush mounted into a concealed housing. The enclosed set of seals is to be used for IP54 installatio

Page 19 - Declaration of CE conformity

484. Start-upThe detectors are supplied ready for operation with a factory setting of re-commended standard values. The QuickSet plus service remote c

Page 20

49Depending on the installation location, natural light intensity, furniture, re-ection characteristics of the room and the furniture it may be neces